UTILITY PACKAGE (GX Configurator-PT)
(2) Items
"Module side Buffer size": Displays the buffer memory size of the setting item.
"Module side Transfer word count": Displays the number of words to be transferred.
"Transfer direction": " " indicates that data are written from the programmable
controller CPU to the buffer memory.
" " indicates that data are loaded from the buffer memory to the programmable
controller CPU.
"PLC side Device": Enter a CPU module side device that is to be automatically
refreshed.
Applicable devices are X, Y, M, L, B, T, C, ST, D, W, R, and ZR.
When using bit devices X, Y, M, L or B, set a number that can be divided by 16 points
(examples: X10, Y120, M16, etc.).
Also, buffer memory data are stored in a 16-point area, starting from the specified
device number. For example, if X10 is entered, data are stored in X10 to X1F.
(3) Command button
End setup
POINT
Creates a file containing the screen data in text file format.
Make text file
Saves the set data and ends the operation.
Cancels the setting and ends the operation.
Cancel
• The auto refresh settings are stored in an intelligent function module
parameter file. The auto refresh settings become effective by turning the
power OFF and then ON or resetting the CPU module after writing the
intelligent function module parameters to the CPU module.
• The auto refresh settings cannot be changed from sequence programs.
However, processing equivalent to auto refresh can be added using the
FROM/TO instruction in the sequence program.