56
OLED User Interface
Enabling and Disabling Auto Pump
System Settings
Auto Pump
Part 1128351_02
S
To toggle the Master Pump control On, press
flashes.
S
If AutoPump is enabled, then the pump button will flash, indicating that
the master pump control will be toggled On as soon as system
temperature ready is achieved. If you press the Master Pump Control
button again, AutoPump becomes disabled, although only for this one
time. When the system temperature ready is achieved, the Master pump
Control remains Off. In this case, pushing the Master Pump Control
button again will switch the Master Pump Control On, since system
Temperature Ready has already been achieved.
NOTE: The Master Pump Control LED flashes while waiting for Temperature
Ready. Once Temperature Ready is reached, the LED stops flashing and
remains illuminated.
CAUTION! When the pump running, the system becomes pressurized.
Enabling and Disabling Auto Pump
1. Select Auto Pump and press the
Pump to Enabled or Disabled. The default is Enabled.
2. Press
or < to return to the Home screen.
The Pump LED
ü
on the Navigation pad to toggle Auto
E 2020 Nordson Corporation