Pressure Runup Pressure Limits; Pressure Runup General Settings - Nordson ProBlue Flex Manual

Adhesive melter using the oled user interface
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

Pressure
Pressure Settings
Pressure Mode
Runup
Pressure
Pressure Settings
Pressure Mode
Runup
E 2020 Nordson Corporation

Pressure Runup Pressure Limits

Enter the maximum/minimum pressure you want the system to use for
production.
1. Select Pressure Limit, press > and enter the following information:
S
Maximum Pressure:
Pressure
Default
PSI
100
BAR
6.90
kPa
690
S
Minimum Pressure:
Pressure
Default
PSI
0
BAR
0
kPa
0
2. When done, press < to return to the Runup Settings menu or
return to the Home screen.

Pressure Runup General Settings

1. Select , press > and enter the following information:
S
Full Scale Line Speed:
Pressure
Default
Meter/
100
minute
Feet/
328
Minute
S
Zero Line Speed Pressure.
Setting
Enabled
Allows the system pressure to remain at the
user-defined Minimum Pressure setting
Disabled
Allows the system pressure to drop to 0 (zero)
2. When done, press < to return to the Pressure Control Settings menu or
to return to the Home screen.
OLED User Interface
Minimum
Maximum
10
100
0.69
6.90
69
690
Minimum
Maximum
0
90
0
6.21
0
621
Minimum
Maximum
1.5
300.2
5
985
Description
39
to
Part 1128351_02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents