8.4

Charging sequence 4

Charging sequence according to connection example 7.4,
local release and locking"
Figure 8-4
Charging sequence 4
EV Charge Control Basic
EV Charge Control basic
IEC 61
85
1-1
Mode 3
CP
12V
9V
6V
3V
0V
-12V
PP[ Ω ]
1500
680
220
100
0
EN
1
0
XR
1
0
ML
1
0
CCR
1
0
C1/
closed
open
C2
+12V
LO+/
0
LO-
-
12
V
LD
1
0
ERR
1
0
CHG
1
0
CON
1
0
S
S
S
1
2
3
S1
S
S
S
4
5
6
"Charging enabled with
1
0
1 2 3 4 5
6
7
8
S
7
106377_en_04