Flow charts for the charging process

S1/DIP 1 = OFF
S1/DIP 5 = OFF
(20 A)
S1/DIP 6 = ON
S1/DIP 5 = ON
(32 A)
S1/DIP 6 = OFF
106377_en_04
The examples are based on the default configurations of the digital inputs and outputs.
8.1

Charging sequence 1

Charging sequence according to connection example 7.1,
local release"
Figure 8-1
Charging sequence 1
EV Charge Control Basic
EV Charge Control basic
IEC 61
85
1-1
Mode 3
CP
12V
9V
6V
3V
0V
-12V
PP[ Ω ]
1500
680
220
100
0
EN
1
0
XR
1
0
ML
1
0
CCR
1
0
C1/
closed
open
C2
+12V
LO+/
0
LO-
-
12
V
LD
1
0
ERR
1
0
CHG
1
0
CON
1
0
S
S
S
1
2
3
S1
S1
S
S
S
S
4
5
6
7
Flow charts for the charging process
"Charging enabled with
20 A
1
0
1 2 3 4 5
6
7
8
32 A
1
0
6
1 2 3 4 5
7
8
S
S
S
S
8
9
10
11
PHOENIX CONTACT
S
12
47 / 68