Power Dissipation

In general, the drive power stages are 90 to 95 percent efficient depending on the actual point
of the torque speed curve the drive is operating. Logic power losses on the E Series drive is
11 W minimum to 21 W depending on external loading such as FM modules and input
voltages. Logic power losses on the Epsilon drive are 11 W with normal loads to 15 W with
additional loads such as external encoder and low input voltage (<22 VDC on A.P.S. or 120
VAC on AC input).
The values shown in the table below represent the typical dissipation that could occur with
the drive/motor combination specified at maximum output power.
Drive Model
EN-204 / MG-205
EN-204 / MG-208
EN-204 / MG-316
EN-208 / MG-340
EN-208 / MG-455
EN-214 / MG-490
EN-214 / MG-4120
Eb-202 / MG-205
Eb-202 / NT-207
Eb-202 / NT-212
Eb-203 / NT-207
Eb-203 / MG-208
Eb-203 / NT-212
Eb-203 / MG-316
Eb-205 / NT-212
Eb-205 / MG-316
Eb-205 / MG-340
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Logic Power Losses
Maximum Power Stage
(typ) Drive
(Pld) (Watts)
(Pp) (Watts)
19
11
Specifications
Total
Losses
Power Losses
(Watts)
30
52
50
72
82
104
160
182
200
222
300
322
430
452
25
36
25
36
30
41
30
41
55
66
55
66
60
71
55
66
72
83
88
99
205