Epsilon Eb and E Series EN Drives Reference Manual
Display Indication

Fault Codes

A number of diagnostic and fault detection circuits are incorporated to protect the drive. Some
faults, like high DC bus and amplifier or motor over temperature, can be reset with the Reset
button on the front of the drive or the Reset input function. Other faults, such as encoder
faults, can only be reset by cycling power "Off" (wait until the status display turns "Off"),
then power "On".
The drive accurately tracks motor position during fault conditions. For example, if there is a
"Low DC Bus" fault where the power stage is disabled, the drive will continue to track the
motor's position provided the logic power is not interrupted.
The +/- Travel Limit faults are automatically cleared when the fault condition is removed.
The table below lists all the fault codes in priority order from highest to lowest. This means
that if two faults are active, only the higher priority fault will be displayed.
Display
112
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Status
Torque
Summation
RMS Foldback
Stall Foldback
(E Series drive only)
Ready to Run
Fault
Power Up Test
Description
Torque mode operation.
Summation mode operation.
Motor torque is limited to 80 percent.
Drive output current is limited to 80 percent of drive
stall current.
Drive enabled, no Stop input.
Action to Reset
Bridge Disabled
Power
Yes