Emerson Epsilon Eb Series Reference Manual page 31

En drives
Table of Contents

Advertisement

Epsilon Eb and E Series EN Drives Reference Manual
Figure 12:
Operating Mode, Torque Mode Selected
2.
Enter a "Full Scale Torque" value. This "Full Scale Torque" value corresponds to an
Analog Full Scale parameter, which is defaulted to a 10V analog command.
Torque Limit Setup
This function can be active in any operating mode.
1.
Enter a "Torque Limit" value. The "Torque Limit" is the value at which the Torque
Command will be limited when the "Torque Limit Enable" input function is active.
2.
Click on the Inputs tab. Assign the "Torque Limit Enable" input function to an input line
by highlighting the function, then selecting one of the "Input Line Selection" radio
buttons or by dragging the highlighted input function to the desired input line.
Torque Level 1 and 2 Setup
This function can be active in any Operating Mode.
1.
Click on the Outputs tab.
2.
Highlight the "Torque Level 1 Active or Level 2 Active" output function in the "Output
Functions" window.
3.
Select an Output Line radio button that corresponds to the output line you wish to assign
this function.
4.
Click on the Torque Setup tab.
5.
Enter a value into the Torque Level 1 and/or Torque Level 2. The Torque Levels
correspond to the Analog Full Scale parameter, which is defaulted to a 10V analog
command.