Figure 85:
CW Electrical Angle Plot
In Figure 84 the electrical angle decreases from left to right and the positive peak of V
occurs at zero degrees electrical. In Figure 85 the electrical angle increases from left to right
and the negative peak of V
rotation the negative peak of V
decreases from left to right.
Note
If you cannot obtain a stable angle measurement between U or Z and V
encoder to verify it has the proper cycles per revolution for your motors pole count.
Establishing a Standard Alignment
A typical encoder alignment practice is to set the rising edge of U to zero crossing of the rising
wave of V
with the motor rotating CCW.
SR
136
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
occurs at zero degrees electrical. Note that with a CW reference
TS
is at zero electrical degrees and the electrical angle
TS
TS
, check the