Bottom View
Output #3
Drive Enable
I/O Supply
I/O Supply
I/O Common
I/O Common
Figure 110:
Epsilon Brake Wiring Diagram using the Command Connector
Front View
Output #3
Drive Enable
I/O Supply
I/O Common
Figure 111:
Epsilon Brake Wiring Diagram using the I/O Connector
Input/Output and Drive Enable Wiring
Drives are equipped with five optically isolated input lines (one is dedicated to a drive enable
function) and three optically isolated output lines. They are designed to operate from a +10
to 30 VDC source. All inputs and outputs are configured as sourcing. You are responsible for
choosing a load that will limit each output's current to less than 150 mA.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Customer
supplied drive
enable contact
17
16
2 Amp
34
Fuse
33
1 Amp
32
Fuse
31
J5
-
+
Single point
PE ground.
24 VDC
Customer
supplied drive
enable contact
8
10
2 Amp
Fuse
19
1 Amp
Fuse
20
J3
-
+
Single point
PE ground.
24 VDC
Installation
CBMS-xxx Cable
Black -
A2
A1
C
K1
B
A
14
11
Red +
Relay:
Motor
EMC #BRM-1
Connected to
grounded
mounting panel.
CBMS-xxx Cable
Black -
A2
A1
C
K1
B
A
14
11
Red +
Relay:
Motor
EMC #BRM-1
Connected to
grounded
mounting panel.
Internal
to Motor
Internal
to Motor