Emerson Epsilon Eb Series Reference Manual page 29

En drives
Table of Contents

Advertisement

Epsilon Eb and E Series EN Drives Reference Manual
Note
The coarsest ratio possible is 10 input counts per motor revolution. Settings below this
will cause an overspeed fault.
5.
If needed, enable the "Following Error Limit" by checking the "Enable" check box.
6.
Enter a value between 0.0010 and 10.000 revolutions of the motor.
Velocity Mode Setup
The following Velocity mode setup procedures assume that you have connected the proper
analog command wiring as described in the " Installation" section of this manual.
Velocity Analog Submode Setup
1.
Select the "Velocity Mode" radio button from the Operating Mode group.
2.
Select the "Analog" submode radio button from the Submode group.
Figure 9:
Operating Mode, Velocity Mode Selected
3.
Enter a "Full Scale Velocity" value. The velocity is equal to the Analog Full Scale
parameter which is defaulted to a 10V analog command.
Velocity Presets Submode Setup
1.
Select the "Velocity Mode" radio button from the Operating Mode group.
2.
Select the "Presets" submode radio button from the Submode group.