Drive Faults

The Active Drive Faults dialog box is automatically displayed whenever a fault occurs. There
are two options in this dialog box: Reset Faults and Ignore Faults.
Figure 73:
Active Drive Faults Dialog Box
Resetting Faults
Some drive faults are automatically reset when the fault condition is cleared. Other faults
require drive power to be cycled or the drive to be "rebooted" in order to be cleared. If you
wish to continue working in the PowerTools software without resetting the fault, click the
Ignore Fault button.
To reset faults that can be reset with the Reset Faults button, simply click the Reset Faults
button in the Drive Faults Detected dialog box or push the Reset button on the front of the
drive where the fault occurred.
Viewing Active Drive Faults
To view all active drive faults, select the View Faults command from the Device menu. The
dialog box displayed is the same as Active Drive Faults dialog box described above.
Rebooting the Drive
To reboot the drive, cycle power or select the Reboot Drive command from the Device menu.
This command reboots the drive attached to the active Configuration Window.