Emerson Epsilon Eb Series Reference Manual page 133

En drives
Table of Contents

Advertisement

Epsilon Eb and E Series EN Drives Reference Manual
Motor Overtemp
This fault is generated when the motor thermal switch is open due to motor over-temperature
or incorrect wiring.
RMS Shunt Power
E
N
E Series Only
This fault is generated when RMS shunt power dissipation is greater than the design rating
of the internal shunt.
Overspeed
This fault occurs in one of two circumstances:
1.
When the actual motor speed exceeds the Overspeed Velocity Limit parameter or 150%
of motor maximum operating speed. This parameter can be accessed with PowerTools
software.
2.
If the combination of command pulse frequency and Pulse Ratio can generate a motor
command speed in excess of the fixed limit of 13000 RPM, an Overspeed Fault will be
activated. In Pulse mode operation and any Summation mode which uses Pulse mode,
the input pulse command frequency is monitored and this calculation is made. For
example, with a Pulse Ratio of 10 pulses per motor revolution, the first pulse received
will cause an Overspeed fault even before there is any motor motion.
Following Error
This fault is generated when the following error exceeds the following error limit (default
following error limit is .2 revs). With PowerTools you can change the Following Error Limit
value or disable in the Position tab. The Following Error Limit is functional in Pulse mode
only.
Travel Limit +/-
This fault is caused when either the + or - Travel Limit input function is active.
All "On"
This is a normal condition during power up of the drive. It will last for less than 1 second. If
this display persists, call EMERSON for service advice.
116
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com