Position Tab

This tab allows you to enable and define the Following Error Limit and view actual operating
parameters.
Figure 56:
Position Tab
Limits Group
Enable Following Error Limit Check Box
Check this box to enable or disable the Following Error Limit.
Following Error Limit
This parameter only has an effect in Pulse mode. The Following Error is the difference
between the Position Command and the Position Feedback. It is positive when the Position
Command is greater than the Position Feedback. If the absolute value of the following error
exceeds the value you enter here, the drive will generate a Following Error Fault (F). All
accumulated Following Error will be cleared when the drive is disabled.
The Following Error Limit is in motor revolutions and has a range of .001 to 10.000
revolutions.