Applications
12.1

Using SINAMICS DCM in shipbuilding

When using SINAMICS DCM in shipbuilding, the following points must be observed:
● Radio interference suppression filters must be used in the armature circuit and in the field
circuit (see Chapter "Connecting (Page 55)")
● For EMC-compliant installation, see Chapter "Connecting (Page 55)".
● Use coated modules (option M08), see Chapter "Ordering information for options and
accessories (Page 26)".
12.2
Connecting an incremental encoder
Note
Because the physical transmission media is more robust, the bipolar connection should
always be used. The unipolar connection should only be used if the encoder type does not
output push-pull signals.
Note
The technical data of the incremental encoder inputs (X177.41 to 48) and further information
on how to connect an incremental encoder are given in Chapter "Connecting (Page 55)".
HTL encoder, bipolar, with zero signal
Improved protection against induced interference is achieved by twisting the signal lines in pairs.
Figure 12-1
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A
Bipolar incremental encoder