6-Pulse Series Connection - Siemens SINAMICS DCM Operating Instructions Manual

Control module
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

10.26.3

6-pulse series connection

Topology
The following diagram shows the topology of a 6-pulse series connection of two
SINAMICS DCM.
Figure 10-79 6-pulse series connection (1)
The following diagram shows the topology of a 6-pulse series connection, where additional
converters are connected in parallel to each of the two 6-pulse converters connected in
series.
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A
Descriptions of functions
10.26 Connecting units in parallel and in series
573

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics dc master

Table of Contents