BOP20 functions
Table 9- 7
Functions
Name
Backlighting
Switch active drive
Units
Access level
Parameter filter
Select status display
User parameter list
Hot swapping
Key operation
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A
9.2 Parameterizing using the BOP20 (Basic Operator Panel 20)
The backlighting can be set using p0007 in such a way that it switches itself off automatically
after the set time if no actions are carried out.
From the BOP perspective, the active drive is defined using p0008 or using the keys "FN" and
"Arrow up".
The units are not displayed on the BOP.
The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected using the BOP.
Using the parameter filter in p0004, the available parameters can be filtered according to their
particular function.
Actual values and setpoints are displayed on the status display.
The status display can be set via p0006.
Parameters can be selected for access using the user parameter list in p0013.
The BOP can be unplugged and plugged while energized.
The ON and OFF keys have a function.
When unplugging, the drives are stopped.
After plugging, the drives must be switched on again.
The ON and OFF keys have no function
Unplugging and plugging has no effect on the drives.
The following applies to the "P" and "FN" keys:
When used in a combination with another key, "P" or "FN" must be pressed before the
other key.