7.3.8

Protective conductor connection and shield support

Shield supports are only required if the system is connected to X521/X531.
Figure 7-13
The bending radii of the cables must be observed (see MOTION-CONNECT description).
Note
Only use screws with a permissible mounting depth of 4-6 mm.
NOTICE
Damage or faulty operation due to incorrect shielding and impermissible cable lengths
If the correct shielding procedures and the permissible cable lengths are not observed, the
machine can be damaged or may malfunction.
• Only use shielded cables.
• Do not exceed the cable lengths stated in the technical data.
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A
Protective conductor connection with M4 screw / 1.8 Nm
Shield connection terminal, Weidmüller company, type: KLBUE CO1, Article number:
1753311001
Shield support and PE conductor connection
Additional system components
7.3 Sensor Module Cabinet-Mounted SMC30
185