Siemens SINAMICS DCM Operating Instructions Manual page 264

Control module
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Commissioning
8.5 Commissioning with the STARTER commissioning tool
⇒ Select the following data from the list fields:
Unit:
Type:
Version:
Target device
address:
Name:
Note
For a download, the bus address assigned here is transferred to the device, but is not
transferred to parameter p0918.
To keep p0918 consistent with the project, after a "Load to target device" a "Load to PG"
must still be performed – and must be repeated after every change to p0918 using BOP20 or
AOP30.
Note
A second CUD for expanding the computing capacity is created in the STARTER as an
independent device, type "DCM Standard (Advanced) CUD [2]".
Explanation: "[2]" is the SINAMICS nomenclature for indexed data. In this case, it is used as
a name - independent of any language for a second CUD inserted in the right-hand slot.
⇒ Click Insert
The selected drive unit is displayed in the project wizard preview window.
262
SINAMICS
DCM Standard CUD for one standard CUD in the left-hand slot
DCM Advanced CUD for one Advanced CUD in the left-hand slot
DCM Standard CUD [2] for a Standard CUD in the right-hand slot
DCM Advanced CUD [2] for an Advanced CUD in the right-hand slot
Actual version
The corresponding bus address of the drive (126 is preset in the drive
device)
Any desired name can be entered in the name box
SINAMICS DCM Control Module
Operating Instructions, 12/2018, A5E34888669A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics dc master

Table of Contents