Siemens SINAMICS DCM Operating Instructions Manual page 154

Control module
Hide thumbs Also See for SINAMICS DCM:
Table of Contents

Advertisement

Connecting
6.16 Connector assignment (terminals, Faston mounting tabs, ribbon cables)
Power interface connecting cable - fuse monitoring equipment
Ribbon cable, 10-pin
Table 6- 36
Assignment X23B
Function
24 V supply
24 V supply
Fuse monitoring
Fuse monitoring
Fuse monitoring
Fuse monitoring
Fuse monitoring
Fuse monitoring
Ground
Ground
Power interface for the Control Module / fuse monitoring or fuse monitoring distributor
152
Pin
Signal name
1
P24
2
P24
3
SICHERUNG_OK
4
SICHERUNG_OK
5
SICHERUNG_OK
6
SICHERUNG_OK
7
SICHERUNG_OK
8
SICHERUNG_OK
9
M
10
M
Operating Instructions, 12/2018, A5E34888669A
Connection values /
comments
22...26 V
22...26 V
24 V logic
24 V logic
24 V logic
24 V logic
24 V logic
24 V logic
SINAMICS DCM Control Module

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics dc master

Table of Contents