Parameter
Description
Speed Reference
P0001
P0002
Motor Speed
P0003
Motor Current
P0004
DC Link Voltage (Ud)
P0005
Motor Frequency
P0006
VFD Status
P0007
Motor Voltage
Motor Torque
P0009
P0010
Output Power
P0012
DI8 to DI1 Status
P0013
DO5 to DO1 Status
P0018
AI1 Value
P0019
AI2 Value
P0020
AI3 Value
P0021
AI4 Value
P0023
Software Version
Accessories Config. 1
P0027
P0028
Accessories Config. 2
P0029
Power Hardware Config. Hexadecimal code
P0030
IGBTs Temperature U
P0031
IGBTs Temperature V
P0032
IGBTs Temperature W
P0033
Rectifier Temperature
Internal Air Temp.
P0034
P0036
Fan Heatsink Speed
P0037
Motor Overload Status
Encoder Speed
P0038
P0040
PID Process Variable
PID Setpoint Value
P0041
P0042
Time Powered
P0043
Time Enabled
P0044
kWh Output Energy
P0045
Fan Enabled Time
P0048
Present Alarm
P0049
Present Fault
P0050
Last Fault
P0051
Last Fault Day/Month
Last Fault Year
P0052
P0053
Last Fault Time
Second Fault
P0054
P0055
Second Fault Day/Month 00/00 to 31/12
P0056
Second Fault Year
P0057
Second Fault Time
P0058
Third Fault
P0059
Third Fault Day/Month
P0060
Third Fault Year
P0061
Third Fault Time
P0062
Fourth Fault
Fourth Fault Day/Month
P0063
P0064
Fourth Fault Year
Fourth Fault Time
P0065
P0066
Fifth Fault
P0067
Fifth Fault Day/Month
Table 5.2: Main reading parameters
Parameter
Setting Range
0 to 18000 rpm
0 to 18000 rpm
0.0 to 4500.0 A
0 to 2000 V
0.0 to 300.0 Hz
0 = Ready
1 = Run
2 = Undervoltage
3 = Fault
4 = Self-tuning
5 = Configuration
6 = DC-Braking
7 = STO
0 to 2000 V
-1000.0 to 1000.0 %
0.0 to 6553.5 kW
0000h to 00FFh
0000h to 001Fh
-100.00 to 100.00 %
-100.00 to 100.00 %
-100.00 to 100.00 %
-100.00 to 100.00 %
0.00 to 655.35
Hexadecimal code
representing the
identified accessories.
Refer to
Chapter 7
OPTIONAL ITEMS AND
ACCESSORIES on page
7-1
according to the available
models and option kits.
Refer to the programming
manual for a complete
code list
-20.0 to 150.0 °C
(-4 °F to 302 °F)
-20.0 to 150.0 °C
(-4 °F to 302 °F)
-20.0 to 150.0 °C
(-4 °F to 302 °F)
-20.0 to 150.0 °C
(-4 °F to 302 °F)
-20.0 to 150.0 °C
(-4 °F to 302 °F)
0 to 15000 rpm
0 to 100 %
0 to 65535 rpm
0.0 to 100.0 %
0.0 to 100.0 %
0 to 65535h
0.0 to 6553.5h
0 to 65535 kWh
0 to 65535h
0 to 999
0 to 999
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0 to 999
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
Energization and Start-Up
Description
P0068
Fifth Fault Year
P0069
Fifth Fault Time
P0070
Sixth Fault
P0071
Sixth Fault Day/Month
Sixth Fault Year
P0072
P0073
Sixth Fault Time
Seventh Fault
P0074
P0075
Seventh Fault Day/Month 00/00 to 31/12
P0076
Seventh Fault Year
P0077
Seventh Fault Time
P0078
Eighth Fault
P0079
Eighth Fault Day/Month
P0080
Eighth Fault Year
P0081
Eighth Fault Time
P0082
Ninth Fault
P0083
Ninth Fault Day/Month
P0084
Ninth Fault Year
Ninth Fault Time
P0085
P0086
Tenth Fault
P0087
Tenth Fault Day/Month
P0088
Tenth Fault Year
P0089
Tenth Fault Time
P0090
Current At Last Fault
P0091
DC Link At Last Fault
P0092
Speed At Last Fault
P0093
Reference Last Fault
P0094
Frequency Last Fault
P0095
Motor Volt. Last Fault
DIx Status Last Fault
P0096
P0097
DOx Status Last Fault
P0800
Phase U Book 1 Temper -20 to 150 ºC (-4 ºF to
Phase V Book 1 Temper
P0801
P0802
Phase W Book 1 Temper -20 to 150 ºC (-4 ºF to
P0803
Phase U Book 2 Temper -20 to 150 ºC (-4 ºF to
P0804
Phase V Book 2 Temper
P0805
Phase W Book 2 Temper -20 to 150 ºC (-4 ºF to
P0806
Phase U Book 3 Temper -20 to 150 ºC (-4 ºF to
P0807
Phase V Book 3 Temoer
Phase W Book 3 Temoer -20 to 150 ºC (-4 ºF to
P0808
P0809
Phase U Book 4 Temper -20 to 150 ºC (-4 ºF to
P0810
Phase V Book 4 Temper
P0811
Phase W Book 4 Temper -20 to 150 ºC (-4 ºF to
P0812
Phase U Book 5 Temper -20 to 150 ºC (-4 ºF to
P0813
Phase V Book 5 Temper
P0814
Phase W Book 5 Temper -20 to 150 ºC (-4 ºF to
Phase U Book 1 Current -1000 to 1000 A
P0815
P0816
Phase V Book 1 Current
P0817
Phase W Book 1 Current -1000 to 1000 A
P0818
Phase U Book 2 Current -1000 to 1000 A
P0819
Phase V Book 2 Current
P0820
Phase W Book 2 Current -1000 to 1000 A
P0821
Phase U Book 3 Current -1000 to 1000 A
P0822
Phase V Book 3 Current
P0823
Phase W Book 3 Current -1000 to 1000 A
Phase U Book 4 Current -1000 to 1000 A
P0824
P0825
Phase V Book 4 Current
Phase W Book 4 Current -1000 to 1000 A
P0826
P0827
Phase U Book 5 Current -1000 to 1000 A
P0828
Phase V Book 5 Current
P0829
Phase W Book 5 Current -1000 to 1000 A
Setting Range
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0 to 999
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0 to 999
00/00 to 31/12
00 to 99
00:00 to 23:59
0.0 to 4000.0 A
0 to 2000 V
0 to 18000 rpm
0 to 18000 rpm
0.0 to 300.0 Hz
0 to 2000 V
0000h to 00FFh
0000h to 001Fh
302 ºF)
-20 to 150 ºC (-4 ºF to
302 ºF)
302 ºF)
302 ºF)
-20 to 150 ºC (-4 ºF to
302 ºF)
302 ºF)
302 ºF)
-20 to 150 ºC (-4 ºF to
302 ºF)
302 ºF)
302 ºF)
-20 to 150 ºC (-4 ºF to
302 ºF)
302 ºF)
302 ºF)
-20 to 150 ºC (-4 ºF to
302 ºF)
302 ºF)
-1000 to 1000 A
-1000 to 1000 A
-1000 to 1000 A
-1000 to 1000 A
-1000 to 1000 A