3.2.12.3 CC11 Connections

The control connections (analog inputs/outputs, digital inputs/outputs) must be done to connector XC1 of the
CC11 Control Electronic Board.
The typical connections and functions are shown in
CW
3
≥5 kΩ
CCW
rpm
amp
3-34 | CFW-11W G2
XC1
Terminal
Factory Default Function
Strip
Positive reference for
1
REF+
potentiometer
2
AI1+
Analog input #1:
speed reference (remote)
3
AI1-
Negative reference for
4
REF-
potentiometer
5
AI2+
Analog input #2:
no function
6
AI2-
Analog output #1:
Speed
7
AO1
AGND
Reference (0 V) for the
8
(24 V)
analog outputs
Analog output #2:
Motor current
9
AO2
AGND
Reference (0 V) for the
10
(24 V)
analog outputs
Reference (0 V) for the
11 DGND*
24 Vdc power supply
Common point of the digital
12
COM
inputs
24 Vdc power supply
13 24 Vcc
Common point of the digital
14
COM
inputs
Digital input #1:
15
DI1
Start / Stop
Digital input #2:
16
DI2
direction of rotation (remote)
Digital input #3:
17
DI3
no function
Digital input #4:
18
DI4
no function
Digital input #5:
19
DI5
jog (remote)
Digital input #6:
20
DI6
2
ramp
nd
21
NF1
Digital output #1 DO1 (RL1):
no fault
22
C1
23
NA1
24
NF2
Digital output #2 DO2 (RL2):
N > N
25 C2 - Speed >
25
C2
X
P0288
26
NA2
27
NF3
Digital output #3 DO3 (RL3):
N* > N
- Speed reference >
28
C3
X
P0288
29
NA3
Figure 3.40: Signals of connector XC1 - Digital inputs as active high
Figure 3.40 on page 3-34
Specifications
Output voltage:+5.4 V, ±5 %
Maximum output current: 2 mA
Differential
Resolution: 12 bits
Signal: 0 to 10 V (R
= 400 kΩ) / 0 to 20 mA / 4 to 20 mA (R
IN
Maximum voltage: ±30 V
Output voltage: -4.7 V, ±5 %
Maximum output current: 2 mA
Differential
Resolution: 11 bits + signal
Signal: 0 to ±10 V (R
= 400 kΩ) / 0 to 20 mA / 4 to 20 mA (R
IN
Maximum voltage: ±30 V
Galvanic Isolation
Resolution: 11 bits
Signal: 0 to 10 V (R
≥ 10 kΩ) / 0 to 20 mA / 4 to 20 mA (R
L
Protected against short-circuit
Connected to the ground (frame) through impedance: 940 Ω resistor
in parallel with a 22 nF capacitor
Galvanic isolation
Resolution: 11 bits
Signal: 0 to 10 V (R
≥ 10 kΩ) / 0 to 20 mA / 4 to 20 mA (R
L
Protected against short-circuit
Connected to the ground (frame) through impedance: 940 Ω resistor
in parallel with a 22 nF capacitor
Connected to the ground (frame) through impedance: 940 Ω resistor
in parallel with a 22 nF capacitor
24 Vdc power supply, ±8 %
Capacity: 500 mA
Note: in the models with the 24 Vdc external control power supply
(CFW11XXXXXOW) the terminal 13 of XC1 becomes an input, i.e., the user
must connect a 24 Vdc power supply for the inverter (refer to the
Safety Stop Function on page
this terminal is an output, i.e., the user has a 24 Vdc power supply available
there
6 isolated digital inputs
High level ≥ 18 V
Low level ≤ 3 V
Input voltage ≤ 30 V
Input current: 11 mA @ 24 Vdc
Contact rating:
Maximum voltage: 240 Vac
Maximum current: 1 A
NC - Normally closed contact
C - Common
NO - Normally open contact
and
Figure 3.41 on page
3-35.
= 500 Ω)
IN
= 500 Ω)
IN
≤ 500 Ω)
L
≤ 500 Ω)
L
Item 7.1.2