4
Select the function to be set.
To change the aspect ratio of the key: Press the [ASP
PERS] button, turning it on.
To reduce/enlarge or move the key: Press the [LOC
SIZE] button, turning it on.
To rotate or change the perspective of the key:
Press the [ROT] button, turning it on. To specify
the direction of rotation, press the [X] button or
[Y] button. To adjust perspective, press the [Z]
button.
5
Use the trackball or Z-ring for the operation.
Pressing the [FINE] button, turning it on, enables fine
adjustment of setting values (fine mode).
Pressing the [X], [Y], or [Z] button, turning it on,
restricts operation to the selected axis or item.
The target bank and resizer, and the current parameter
and its value, are displayed in the display of the device
control block.
The correspondence between the operation buttons
and parameters is shown in the following table.
Operation
Parameter Trackball
buttons
(horizontal
rotation)
[X] button [Y] button [Z] button
ASP
Aspect
Change
PERS
aspect ratio
on X-axis
LOC SIZE Location
Move image
on X-axis
ROT
Rotation/
Rotate
Perspective
image on Y-
axis
To enter parameters
Operates identically to DME three-dimensional parameter
input.
For details, see "Three-Dimensional Parameter Entry"
(page 205).
To reset parameters
Operates identically to DME three-dimensional parameter
reset.
For details, see "Resetting three-dimensional
parameters" (page 206).
Trackball
Z-ring
(vertical
rotation)
Change
Change aspect
aspect
ratio on X- and
ratio on Y-
Y-axes
axis
simultaneously
Move
Magnify and
image on
shrink image
Y-axis
Rotate
Change
image on
distance of
X-axis
viewpoint
position
123
To return the resizer to default state (clear work
buffer)
To clear and reset to default state only the two-dimensional
transform and rotation parameters contained in the work
buffer, depending on the resizer operation, press the [CLR
WORK BUFR] button in the device control block.
To clear all of the parameters in the work buffer and reset
the resizer, press the [CLR WORK BUFR] button twice in
rapid succession.
For the default state, you can select either the factory
default settings or user settings.
For details, see "Power-On (Startup) State Selection"
(page 366).
To reset the bank to the default state
Press the [M/E DEF RCALL] button twice in rapid
succession to return the currently selected bank (M/E or
PGM/PST) to the default state.

Rotation Settings

Note
Select either X or Y direction for rotation. You cannot
make rotation by combining both directions.
1
In the M/E-1 >Key1 >Resizer menu (1115), press
[Resizer], turning it on.
2
In the <Resizer Effect/Rotation> group, press
[Rotation].
The Rotation menu (1115.5) appears.
3
In the <Rotation> group, select the direction of
rotation.
X: Horizontal rotation
Y: Vertical rotation
4
Set the following parameters.
When [X] is selected
No.
Parameter Adjustment
1
Rotation X
Horizontal key rotation
4
Perspective Perspective
When [Y] is selected
No.
Parameter Adjustment
2
Rotation Y
Vertical key rotation
4
Perspective Perspective