Assigning Functions To 1St Row/2Nd Row Buttons Of The Cross-Point Control Block - Sony XVS Series User Manual

Multi format switcher system with icp-x7000 integrated control panel
Hide thumbs Also See for XVS Series:
Table of Contents

Advertisement

Command name
Macro AT with A/B Bus
Macro TL with Region
DME Override
DME Graphic
FTB
a) The safe title enable/disable commands display the name of the signal
assigned to the output.
Setting names to display in memory recall
buttons
You can set the display of names on buttons when menu
shortcuts or utility commands are assigned to the memory
recall buttons.
Note
When a macro register is assigned, the names specified in
the Macro menu are displayed on the memory recall
buttons. When a shotbox register is assigned, the names
specified in the Shotbox menu are displayed on the
memory recall buttons.
1
In the Engineering Setup >Panel >Prefs/Utility
>Utility Module Assign menu (7324.1), select the
target button to set.
2
Press [Name].
3
Enter a name of up to 8 characters in the keyboard
window, and press [Enter].
Setting the transition rate target to display
on memory recall buttons
This sets the memory recall button assignments in
transition rate display mode.
1
In the Engineering Setup >Panel >Prefs/Utility
>Utility Module Assign menu (7324.1), press [Trans
Rate Mode Assign].
The Trans Rate Mode Assign menu (7324.3) appears.
Function
Mode enable/disable for storing A/B
bus cross-points when registering an
auto transition macro event on the
transition control block or transition
control block (simple type)
Mode enable disable for saving target
regions when registering a timeline
macro event
DME override enable/disable
DME graphics enable/disable
(applies to graphics for channel
selected in device control block)
Fade-to-black execution
2
3
4
To release the assignment
Select the target button to release, then press [Clear].
Assigning Functions to 1st Row/2nd
Row Buttons of the Cross-Point
Control Block
You can assign functions to the 1st row/2nd row buttons of
the cross-point control block (utility/shotbox mode).
1
2
3
389
Button state
Lit orange
Enabled
Enabled
Enabled
Enabled
Lit light purple during
execution
Lit red when
execution completed
(image in black state)
Select the target button to set.
Select the transition rate to assign.
Press [Set].
In the Engineering Setup >Panel >Prefs/Utility menu
(7324), press [Xpt Module Assign].
The Xpt Module Assign menu (7324.2) appears.
Select the target button to set.
No.
Parameter Adjustment
1
Bank
Bank selection
2
Button No
Button selection
In the <Action> group, select the function to assign.
Menu Shortcut: Assign a frequently used menu to be
recalled (menu shortcut).
Utility Command: Assign a function setting (utility
command).
Macro Recall: Assign a macro register recall.
Shotbox Recall: Assign a shotbox register recall.
Lit dark blue
Disabled
Disabled
Disabled
Disabled
Function assigned (lit
purple)

Advertisement

Table of Contents
loading

Table of Contents