Parameter
6
Parameter
6.1

Parameter overview

For simple variable-speed operation of the inverter, the initial setting of the parameters may be used
as they are. Set the necessary parameters to meet the load and operational specifications. Parameter
setting, change and check can be made from the operation panel.
indicates simple mode parameters (initially set to extended mode).
The abbreviations in the explanations below are as follows:
V/F
V/F
V/F
AD MFVC
AD MFVC
AD MFVC
GP MFVC
GP MFVC
GP MFVC
Parameters without any indication are valid for all control. The half-tone screened parameters allow
its setting to be changed during operation even if "0" (initial value) is set in Pr. 77 "Parameter write se-
lection".
Parameter
Func-
Name
tion
0
Torque boost
Second torque boost
46
1
Maximum frequency
2
Minimum frequency
High speed maximum
18
frequency
Tab.6-1:
Parameter overview (1)
FR-E700SC EC
............ V/F control
............ Advanced magnetic flux vector control
............ General-purpose magnetic-flux vector control
Incre-
Initial
ments
Value
0.1%
6/4/3/2 *
0.1%
9999
0.01Hz
120Hz
0.01Hz
0Hz
0.01Hz
120Hz
Setting
Description
Range
Set the output voltage at 0Hz as %
* Initial values differ according to the inverter
capacity:
FR-E720S-050SC or less,
FR-E740-026SC or less/
0–30%
FR-E720S-080SC and 110SC,
FR-E740-040SC to 095SC/
FR-E740-120SC and 170SC/
FR-E740-230SC and 300SC
Set the torque boost when the RT signal is
0–30%
on.
9999
Without second torque boost
0–120Hz
Set the upper limit of the output frequency
0–120Hz
Set the lower limit of the output frequency
Set when performing operation at 120Hz or
120–400Hz
more
Parameter overview
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled
6-33
6-50
6 - 1