Mitsubishi Electric FR-E700 Series Instruction Manual page 401

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Parameter
● Multi command HF0
Sending data format from computer to inverter
Format
A3
Reply data from the inverter to the computer (no data error detected)
Format
C1
Specify the data type of sending data (from computer to inverter).
Specify the data type of reply data (from inverter to computer).
Combination of data 1 and data 2 for sending.
Data Type
0
1
Tab. 6-82: Data type of sending data
Combination of data 1 and data 2 for reply
Data Type
0
1
Tab. 6-83: Data type of reply data
Error code for sending data 1 is set in error code 1, and error code for sending data 2 is set in error
code 2. Mode error (HA), instruction code error (HB), data range error (HC) or no error (HF) is
replied.
FR-E700SC EC
1
2
3
4
5
6
Instruction
Wait-
Inverter station
ENQ
code
ing
number
(HF0)
time
1
2
3
4
5
6
Send
Receive
Error
STX Inverter station
data
data
code 1
number
type
type
Data 1
Run command
Set frequency
(expansion)
Run command
Set frequency
(expansion)
(RAM, E²PROM)
Data 1
Inverter status monitor
Output frequency
(expansion)
Inverter status monitor
Special monitor
(expansion)
Communication operation and setting
Number of Characters
7
8
9
10
11
Send
Receive
data
data
Data 1
type
type
Number of Characters
7
8
9
10
11
Error
code 2
Data 1
Data 2
Remarks
Run command (expansion) is same as instruction code HF9 (refer to page 6-255).
(RAM)
The unit of set frequency is always by four digits, even when "0.01to 9998" is set in
Pr. 37 and "01" is set in instruction code HFF.
Data 2
Remarks
Inverter status monitor (expansion) is same as instruction code H79 .
(speed)
(Refer to page 6-255)
The unit of speed monitor is always by four digits (rounds down after the decimal
point), even when "0.01 to 9998" is set in Pr. 37 and "01" is set in instruction code
HFF.
Replies the monitor item specified in instruction code HF3 for special monitor.(
Refer to page 6-253)
12
13
14
15
16
17
Sum check
Data 2
12
13
14
15
16
17
ETX
Sum check
Data 2
18
19
CR/LF
18
19
CR/LF
6 - 257

Hide quick links:

Advertisement

Table of Contents
loading