Mitsubishi Electric FR-E700 Series Instruction Manual page 171

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Parameter
Parameter
Func-
Name
tion
495
Remote output selection
496
Remote output data 1
497
Remote output data 2
502
Refer to Pr. 124
503
Maintenance timer
Maintenance timer alarm
504
output set time
USB communication station
547
number
USB communication check
548
time interval
Refer to Pr. 338 to Pr. 339
551
549
Refer to Pr. 117 to Pr. 124
550
Refer to Pr. 338 and Pr. 339
551
Tab. 6-1:
Parameter overview (27)
These parameters are communication parameters that are not cleared when parameter clear (all
clear) is executed from RS-485 communication. (Refer to section 6.19 for RS-485 communica-
tion.)
FR-E700SC EC
Incre-
Initial
Setting
ments
Value
Range
0
1
1
0
10
11
1
0
0–4095
1
0
0–4095
1
0
0 (1–9998)
0–9998
1
9999
9999
1
0
0–31
0
0.1s
9999
0.1–999.8s
9999
Description
Remote output
data clear at pow-
ering off
Remote output data
clear at inverter reset
Remote output
data retention at
powering off
Remote output
data clear at pow-
Remote output data
ering off
retention at inverter
Remote output
reset
data retention at
powering off
Output terminal can be switched on and off.
Display the cumulative energizing time of
the inverter in 100h increments. Reading
only
Writing the setting of "0" clears the cumula-
tive energizing time.
Set the time taken until when the mainte-
nance timer alarm output signal (Y95) is
output.
No function
Specifies the inverter station number.
USB communication is enabled. However,
the inverter will come to an alarm stop
(E.USB) if operation is changed to PU opera-
tion mode.
Set the interval of communication check
time.
No communication check
Parameter overview
All
Para-
Para-
Para-
meter-
meter
meter
Copy
Clear
Refer
Clear
to
Page
✔: Enabled
—: Disabled
6-133
6-307
6-276
6 - 27