Regeneration Avoidance Function - Mitsubishi Electric FR-E700 Series Instruction Manual

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Special operation
6.20.4
Regeneration avoidance function (Pr. 665, Pr. 882, Pr. 883, Pr. 885, Pr. 886)
This function detects a regeneration status and increases the frequency to avoid the regeneration sta-
tus.
Possible to avoid regeneration by automatically increasing the frequency and continue operation if
the fan happens to rotate faster than the set speed due to the effect of another fan in the same duct.
Pr. No.
Name
Regeneration avoidance
882
operation selection
Regeneration avoidance
883
operation level
Regeneration avoidance
885
compensation frequency
limit value
Regeneration avoidance
886
voltage gain
Regeneration avoidance
665
frequency gain
The above parameters can be set when Pr. 160 "User group read selection" = 0.
6 - 298
Setting
Initial Value
Description
Range
0
Regeneration avoidance function invalid
1
Regeneration avoidance function is always valid
0
Regeneration avoidance function is valid only
2
during a constant speed operation
200V
Set the bus voltage level at which regeneration
400V
class
avoidance operates. When the bus voltage level is
set to low, overvoltage error will be less apt to
300–800V
occur. However, the actual deceleration time
400V
780V
increases. The set value must be higher than the
class
power supply voltage
Set the limit value of frequency which rises at
0–10Hz
activation of regeneration avoidance function.
6Hz
9999
Frequency limit invalid
Responsiveness at activation of regeneration
100%
0–200%
avoidance. A larger setting will improve respon-
siveness to the bus voltage change. However, the
output frequency could become unstable. When
100%
0–200%
vibration is not suppressed by decreasing the Pr.
886 setting, set a smaller value in Pr. 665.
Parameters referred to
1
8
22
×
2
.
Parameter
Refer to
Section
Maximum
6.4.1
frequency
Deceleration time
6.7.1
Stall prevention
6.3.5
operation level

Hide quick links: