Mitsubishi Electric FR-E700 Series Instruction Manual page 92

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Operation panel
Key
Tab. 4-3:
4 - 8
Function
Digital dial
Rotation direction
Stop operation/
Fault reset
Mode switch over
Write settings
Operation mode
switch over
Keys of the operation panel
Description
Used to change the frequency setting and parameter values.
Press to display the following.
Displays the set frequency in the monitor mode
Currently set value is displayed during calibration
Displays the order in the faults history mode
RUN command for forward/reverse rotation.
The rotation direction can be selected by setting Pr. 40.
Used to stop RUN command.
Fault can be reset when protective function is activated (fault).
Used to change each setting mode.
Pressing PU/EXT simultaneously changes the operation mode (refer
to section 4.3.3).
Pressing for a while (2s) can lock operation (refer to section 4.3.4).
If pressed during operation, monitor changes as below:
Running
Output
frequency
current
Used to switch between the PU and external operation mode. When
using the external operation mode (operation using a separately con-
nected frequency setting potentiometer and start signal), press this key
to light up the EXT indication. (Press MODE simultanesouly (0.5s) or
change Pr. 79 setting to change to combined mode.)
PU: PU operation mode
EXT: External operation mode (Cancels PU stop also.)
Operation
Output
voltage