Acceleration And Deceleration; Acceleration And Deceleration Time - Mitsubishi Electric FR-E700 Series Instruction Manual

Hide thumbs Also See for FR-E700 Series:
Table of Contents

Advertisement

Parameter
6.7

Acceleration and deceleration

Purpose
Motor acceleration/deceleration time
setting
Starting frequency
Set acceleration/deceleration
pattern suitable for application
Automatically set optimum
acceleration/deceleration time
6.7.1

Acceleration and deceleration time

(Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45, Pr. 147)
Used to set motor acceleration/deceleration time. Set a larger value for a slower speed increase/de-
crease or a smaller value for a faster speed increase/decrease.
Pr. No. Name
FR-E720S-110SC or less,
FR-E740-095SC or less
7
Acceleration time
FR-E740-120SC and 170SC
FR-E740-230SC and 300SC
FR-E720S-110SC or less,
FR-E740-095SC or less
8
Deceleration time
FR-E740-120SC and 170SC
FR-E740-230SC and 300SC
Acceleration/
deceleration
20
reference
frequency
Acceleration/
21
deceleration time
increments
FR-E720S-110SC or less,
Second accelera-
FR-E740-095SC or less
44
tion/deceleration
FR-E740-120SC and 170SC
time
FR-E740-230SC and 300SC
Second decelera-
45
tion time
Acceleration/
deceleration time
147
switching fre-
quency
The above parameters can be set when Pr. 160 "User group read selection" = 0.
Depends on the Pr. 21 "Acceleration/deceleration time increments" setting. The initial value for
the setting range is "0 to 3600s" and the setting increments is "0.1s".
FR-E700SC EC
Parameters that must be set
Acceleration/deceleration times
Starting frequency and start-time hold
Acceleration/deceleration pattern
Automatic acceleration/deceleration
Setting
Initial Value
Range
5s
0–3600s/
10s
0–360s
15s
5s
0–3600s/
10s
0–360s
15s
50Hz
1–400Hz
0
0
1
5s
0–3600s/
10s
0–360s
15s
0–3600s/
0–360s
9999
9999
0–400Hz
9999
9999
Description
Set the motor acceleration time.
Set the motor deceleration time.
Set the frequency that will be the basis
of acceleration/deceleration time.
As acceleration/deceleration time, set
the frequency change time from stop to
Pr. 20.
Increments:
0.1s
Increments and set-
Range:
ting range of accel-
0–3600s
eration/
deceleration time
Increments:
setting can be
0.01s
changed.
Range:
0–360s
Set the acceleration/deceleration time
when the RT signal is on.
Set the deceleration time when the RT
signal is on.
Acceleration time = deceleration time
Frequency when automatically switch-
ing to the acceleration/deceleration
time of Pr. 44 and Pr. 45.
No function
Acceleration and deceleration
Refer to
Section
Pr. 7, Pr. 8, Pr. 20,
6.7.1
Pr. 21, Pr. 44,
Pr. 45, Pr. 147
Pr. 13, Pr. 571
6.7.2
Pr. 29
6.7.3
Pr. 61–Pr. 63,
6.7.4
Pr. 292
Parameters referred to
3
Base frequency
29
Acceleration/deceleration
pattern selection
125
Frequency setting gain
frequency
126
Frequency setting gain
frequency
178–184
Input terminal function
selection
Refer to
Section
6.5.1
6.7.3
6.16.3
6.16.3
6.10.1
6 - 69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents