Juniper M120 Hardware Manual page 305

Multiservice edge router
Hide thumbs Also See for M120:
Table of Contents

Advertisement

Copyright © 2018, Juniper Networks, Inc.
Start time:
Uptime:
You can also issue the
show chassis environment feb
a specific FEB. In the example below, the FEB is slot
the following:
user@host> show chassis environment feb 0
FEB 0 status:
State
Temperature Intake
Temperature Exhaust A
Temperature Exhaust B
Power
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
1.2 V Rocket IO
1.5 V Rocket IO
1.8 V RLDRAM
I2C Slave Revision
To take a FEB offline or online or restart it, click
feb (online | offline | restart) slot slot-number
NOTE:
If you bring a FEB offline (or remove it), interfaces on FPCs
connected to the FEB are deleted. When you bring the FEB back online, the
interfaces are restored.
Plan FEB redundancy groups according to your network requirements.
A FEB redundancy group is a named collection of two or more Forwarding Engine
Boards (FEBs) that can improve interface availability. You can design your redundant
FEB configuration to provide backup on a one-to-one basis, or you can provide one
backup for multiple FEBs. Each FEB redundancy group can contain only one primary
FEB.
To create or edit FEB redundancy groups, use the
feb-redundancy group group-name
Change the default assignments of FPCs to FEBs according to your network
requirements. By default, each FPC is assigned to the FEB of the same identifying
number; for example, FPC 1 is assigned to FEB 1.
To assign an FPC to a FEB, use the
hierarchy level. You can also map an FPC to
mapped to any FEB. (When an FPC is configured not to connect to any FEB, interfaces
on that FPC are not created; however, no alarm is triggered.)
To view which FPCs are mapped to which FEBs and the status of each link, enter
the
show chassis fpc-feb-connectivity
Chapter 31: Maintaining Components and Cables
2006-09-08 16:29:59 PDT
1 hour, 3 minutes, 4 seconds
command to check the status of
0
is used. The output is similar to
Online
66 degrees C / 150 degrees F
67 degrees C / 152 degrees F
73 degrees C / 163 degrees F
1153 mV
1417 mV
1704 mV
2375 mV
3138 mV
4763 mV
1160 mV
1408 mV
1717 mV
15
,
Offline
Online
command.
edit chassis redundancy
command.
statement at the
fpc-feb-connectivity
to specify that the FPC is not
none
command.
, enter the
request chassis
[edit chassis]
279