Installing A M120 Dimm Module - Juniper M120 Hardware Manual

Multiservice edge router
Hide thumbs Also See for M120:
Table of Contents

Advertisement

See Also

Installing a M120 DIMM Module

Copyright © 2018, Juniper Networks, Inc.
Place an electrostatic bag or antistatic mat on a flat, stable surface.
1.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to one of the ESD points on the chassis.
Remove the Routing Engine.
3.
Depending on which Routing Engine you are using, there are two different procedures
4.
for ejecting the DIMMs:
For Routing Engines with an ejector on one side of the DIMM, press the plastic ejector
of the DIMM module. The edge of the module raises upward.
For Routing Engines with ejectors on each side of the DIMM, press the plastic ejectors
on both sides of the DIMM module.
Grasp the DIMM module, being careful not to touch any electrical components on the
5.
module, and firmly pull it out of the slot on the Routing Engine.
Place the DIMM module on the antistatic mat or in the electrostatic bag.
6.
Push the plastic ejectors to close the empty DIMM module slot.
7.
M120 Routing Engine Description on page 22
Replacing an M120 Routing Engine on page 195
Installing a M120 DIMM Module on page 201
NOTE:
When installing DIMMs on an RE-1800, make sure that all DIMMs are
manufactured by the same vendor. If necessary, replace an existing DIMM
with a new DIMM.
To insert a DIMM module into the Routing Engine:
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
Remove the DIMM module from its electrostatic bag.
2.
To open the empty DIMM slot, press the plastic ejectors open.
3.
Grasp the DIMM module by the edges, being careful not to touch any electrical
4.
components.
Pressing firmly on both ends, push the module into the slot until the ejectors return
5.
completely to the closed position.
Install the Routing Engine.
6.
You can view the the SDRAM configuration and verify the DIMM was installed correctly
7.
by issuing the
show chassis routing-engine
Chapter 26: Replacing Host Subsystem Components
command.
201