Place one hand around the front of the CFPC and the other hand under it to support
7.
it. Slide the CFPC completely out of the chassis, and place it on the antistatic mat or
in the electrostatic bag.
CAUTION:
When the CFPC is out of the chassis, do not hold it by the ejector
handle, bus bars, or edge connectors. They cannot support its weight.
Place each individual CFPC in an individual electrostatic bag or on its own
antistatic mat on a flat, stable surface.
If you are not reinstalling a CFPC into the emptied CFPC slot within a short time, install
8.
a blank CFPC panel over the slot to maintain proper airflow within the router.
CAUTION:
After removing a CFPC from the chassis, wait at least 30
seconds before reinserting it, removing a CFPC from a different slot, or
inserting a CFPC into a different slot.

Figure 87: Removing an M120 CFPC

M120 Compact FPCs (CFPCs) Description on page 54
Maintaining M120 FPCs and CFPCs on page 270
Troubleshooting M120 FPCs and CFPCs on page 287