Installing the Mounting Hardware for a Center-Mount Open-Frame Rack

Copyright © 2018, Juniper Networks, Inc.

Figure 30: Installing the M120 Mounting Hardware for an Open-Frame Rack

Large
mounting shelf
M120 Rack Mounting Requirements on page 83
M120 Site Preparation Checklist on page 81
Installation Safety Warnings for Juniper Networks Devices on page 322
If you are installing the router in a center-mount open-frame rack, you must first install
the large mounting shelf on the rack. The spacer bars are not needed for this mounting
option; however, you can leave them attached to the front-mounting flanges.
Table 66 on page 121
specifies the holes in which you insert screws to install the mounting
hardware in an open-frame rack (an X indicates a mounting hole location). The hole
distances are relative to one of the standard U divisions on the rack. For reference, the
bottom of all mounting shelves is at 0.04 in. (0.02 U) above a U division.
To install the large mounting shelf (see