[Al. 037_Parameter Error] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 037_Parameter error]

• Servo parameter setting values are incorrect.
[AL. 037.1_Parameter setting range error]
Cause
1.
A parameter was set outside of the setting
range.
2.
An inconsistent combination of parameters
has been set.
3.
The setting value of the parameter has
changed due to the servo amplifier
malfunction.
[AL. 037.2_Parameter combination error]
Cause
1.
An inconsistent combination of parameters
has been set.
[AL. 037.6_Parameter mismatch error]
Cause
1.
Mismatching with the saved parameters
occurred because of the error in writing
parameters.
2.
The setting value of the parameter changed as
the servo amplifier malfunctioned.
[AL. 037.7_Network parameter setting error]
Cause
1.
There is a problem with the network parameter
settings.
2.
The setting value of the network parameter
changed as the servo amplifier malfunctioned.
1 SERVO AMPLIFIER TROUBLESHOOTING
56
1.3 Handling methods for alarms/warnings
Check/action method
[A]: Check the parameter error No. on the parameter error No. display screen
of the servo amplifier display, the alarm display screen of MR Configurator2, or
with another method, and review the setting value of the parameter.
[G] [WG]: Check the parameter error No. on the alarm display screen of MR
Configurator2 or with another method, then review the setting value of the
parameter.
[A]: Check the parameter error No. on the parameter error No. display screen
of the servo amplifier display, the alarm display screen of MR Configurator2, or
with another method, and review the setting value of the parameter.
[G] [WG]: Check the parameter error No. on the alarm display screen of MR
Configurator2 or with another method, then review the setting value of the
parameter.
Replace the servo amplifier.
Check/action method
[A]: Check the parameter error No. on the parameter error No. display screen
of the servo amplifier display, the alarm display screen of MR Configurator2, or
with another method, and review the setting value of the parameter.
[G] [WG]: Check the parameter error No. on the alarm display screen of MR
Configurator2 or with another method, then review the setting value of the
parameter.
Check/action method
[A]: Check the parameter error No. on the parameter error No. display screen
of the servo amplifier display, the alarm display screen of MR Configurator2, or
another method. Rewrite the setting value because the value before or after
writing has been displayed.
[G] [WG]: Check the servo parameter error No. on the alarm display screen of
MR Configurator2 or with another method. Rewrite the setting value because
the value before or after writing has been displayed.
Replace the servo amplifier.
Check/action method
Check if the setting value of the network parameter is within the setting range.
[A]: Check the parameter error No. on the parameter error No. display screen
of the servo amplifier display, the alarm display screen of MR Configurator2, or
another method. Rewrite the setting value because the value before or after
writing has been displayed.
[G] [WG]: Check the servo parameter error No. on the alarm display screen of
MR Configurator2 or with another method. Rewrite the setting value because
the value before or after writing has been displayed.
Replace the servo amplifier.
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]

Hide quick links: