[Al. 01E_Encoder Initial Communication Error 2] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 01E_Encoder initial communication error 2]

• The encoder has malfunctioned.
[AL. 01E.1_Encoder malfunction]
Cause
1.
The encoder has malfunctioned.
2.
There is a problem with the surrounding
environment.
[AL. 01E.2_Load-side encoder malfunction]
Cause
1.
The load-side encoder has malfunctioned.
2.
There is a problem with the surrounding
environment.
1 SERVO AMPLIFIER TROUBLESHOOTING
36
1.3 Handling methods for alarms/warnings
Check/action method
Replace the servo motor.
Check the noise, ambient temperature, and other conditions, and implement
appropriate countermeasures for the cause.
If there is noise, take countermeasures to reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Check/action method
Replace the load-side encoder.
Check the noise, ambient temperature, and other conditions, and implement
appropriate countermeasures for the cause.
If there is noise, take countermeasures to reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Model
[A]
[G]
[WG]
Model
[A]
[G]
[WG]