[Al. 012_Memory Error 1 (Ram)] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 012_Memory error 1 (RAM)]

• The internal part of the servo amplifier (RAM) has malfunctioned.
[AL. 012.1_RAM error 1]
Cause
1.
An internal part of the servo amplifier has
malfunctioned.
2.
There is a problem with the surrounding
environment.
[AL. 012.2_RAM error 2]
Page 26 [AL. 012.1_RAM error 1]
[AL. 012.4_RAM error 4]
Page 26 [AL. 012.1_RAM error 1]
[AL. 012.5_RAM error 5]
Page 26 [AL. 012.1_RAM error 1]
[AL. 012.6_RAM error 6]
Page 26 [AL. 012.1_RAM error 1]
[AL. 012.7_RAM error 7]
Page 26 [AL. 012.1_RAM error 1]
[AL. 012.8_RAM error 8]
Page 26 [AL. 012.1_RAM error 1]
[AL. 012.9_RAM error 9]
Page 26 [AL. 012.1_RAM error 1]
1 SERVO AMPLIFIER TROUBLESHOOTING
26
1.3 Handling methods for alarms/warnings
Check/action method
Noise from the power supply may have caused the failure. Disconnect all
cables except for those for the control circuit power supply, then check the
repeatability. If the failure continues, the servo amplifier may have
malfunctioned. Replace the servo amplifier.
Check the power supply for noise. If there is noise, take countermeasures to
reduce the noise.
Refer to "Noise reduction techniques" in the following manual.
MR-J5 User's Manual (Hardware)
Model
[A]
[G]
[WG]

Hide quick links:

Advertisement

Table of Contents
loading