1.7 Error Status

If an error has occurred in GX Developer, the following dialog appears. The error message and
error status are displayed in the dialog.
(Note) When an error occurred at GX Developer On-line function, the error message may not
explain exactly the state in the CNC side.
Always refer to the error list.
The following table indicates the causes and remedies of the errors that can occur during online
operation with the CNC. For other errors, refer to the GX Developer operating manual.
Status
2056
The executed function is not
supported.
4002
Cannot communicate with the
PLC.
4010
The PLC is in RUN mode, so
writing cannot be done.
4021
The applicable drive is not
ready.
4029
Insufficient file capacity.
402b
The file cannot be accessed.
4031
The specified device No.
exceeds the permissible
range.
4052
The file is write protected.
4053
Writing to the flash ROM
failed.
1.7 Error Status
(2) Error status
Message
An attempt was made to
execute a function not
supported.
The version of GX Developer
used is not compatible to the
CNC.
An operation outside the
specification was performed.
The PLC of the NC is running.
The specified target memory
does not exist or is not in a
usable status.
An attempt was made to write
a file that exceeds the storage
capacity.
An attempt was made to write
the same type of file.
The access request given is
outside the accessible device
range.
The specified target memory is
a write-disabled device
(F-ROM).
An error occurred in the
process to erase or to write
data into the flash ROM.
- 49 -
Get other manuals https://www.bkmanuals.com
(1) Error message
Cause
Check the specifications.
This error occurs when the GX
Developer version is one of
7.10L to 7.14Q. Download
from MELFANSweb to update
the version to 7.17T or higher.
Check the storage capacity or
the operation procedure.
After stopping the PLC of the
NC, start execution again.
Change the target memory.
Examine the file structure so
that the data falls within the
limited capacity.
After deleting the same type of
file from the NC side, start
execution again.
Check the number range of
each device.
Specify "internal RAM" as the
target memory.
The hardware may have
inferiority or deterioration
aspects.
Contact our system department.
Remedy

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64

Table of Contents