[Al. 564_Increment Monitor Error (Safety Sub-Function)] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 564_Increment monitor error (safety sub-function)]

• There is a problem with the travel distance in the safety sub-function.
[AL. 564.1_SLI feedback position exceeded A]
Cause
1.
The feedback position moved by a distance
exceeding the permissible travel distance set
in [Pr. PSB02 SLI permissible travel distance -
Positive direction 1] or [Pr. PSB06 SLI
permissible travel distance - Negative direction
1] after operation of the SLI function.
2.
Take actions according to the instructions of 2. to 6. in the following item.
Page 180 [AL. 563.1_SS1 feedback speed exceeded A]
[AL. 564.9_SLI feedback position exceeded B]
Page 182 [AL. 564.1_SLI feedback position exceeded A]
1 SERVO AMPLIFIER TROUBLESHOOTING
182
1.3 Handling methods for alarms/warnings
Check/action method
Review the parameter or the operation pattern.
Check if the SLI command was input before the motor stopped.
Refer to "SLI function" in the following manual.
MR-J5 User's Manual (Function)