[AL. 011_Switch setting error]

• The settings of the DIP switch are incorrect.
• The settings of the rotary switch are incorrect.
[AL. 011.1_Rotary switch setting error]
Cause
1.
Each selected network has its settable range,
and the values set with the rotary switches
(SW1/SW2) were set out of the range.
[AL. 011.2_Disabling control axis setting error]
Cause
1.
The settings of the disabling control axis
switch are incorrect.
Check/action method
Check the settings of the rotary switches (SW1/SW2).
If the value set with the rotary switch does not match the actual value, the
servo amplifier may have malfunctioned. Replace the servo amplifier.
Specifications on the setting of the rotary switches vary depending on each
network.
Refer to "Switch setting and display of the servo amplifier" in the User's
Manual (Introduction).
Check/action method
Check the setting of the disabling control axis switch.
Refer to "Switch setting and display of the servo amplifier" in the User's
Manual (Introduction).
If the above case does not apply, the servo amplifier may have malfunctioned.
Replace the servo amplifier.