[AL. 028_Linear encoder error 2]

• There is a problem with the operating environment of the linear encoder.
[AL. 028.1_Linear encoder environmental error]
Cause
1.
The ambient temperature of the linear encoder
is outside of specifications.
2.
The signal level of the linear encoder dropped.
3.
The temperature detection circuit of the linear
encoder has malfunctioned.
[AL. 028.2_Load-side linear encoder environmental error]
Page 47 [AL. 028.1_Linear encoder environmental error]
Check/action method
Check the ambient temperature and the specifications of the linear encoder.
Check the mounting condition of the linear encoder.
Contact the manufacturer of the linear encoder.