[AL. 19E_Network warning 2]

• An error exists in the network settings.
[AL. 19E.1_Parameter automatic backup setting warning]
Cause
1.
An error was detected in the parameter
automatic backup setting.
[AL. 19E.2_Control mode setting warning 2]
Cause
1.
An unsupported control mode was used.
[AL. 19E.3_Safety communication setting warning]
Cause
1.
The safety communication setting of the
controller has been enabled for a servo
amplifier on which the safety communication
has been disabled.
Check/action method
Check if the master station supports power interruption protection.
If power interruption protection is not supported, set [Pr. PN20] to "0" to disable
the automatic backup function.
Check/action method
Check if the control mode corresponds to the communication cycle.
For the correspondence between communication cycles and control modes,
refer to "Function restrictions" in the User's Manual (Introduction).
Check/action method
If not using the safety communication, disable the safety communication
setting of the controller.
If using the safety communication, enable the safety communication setting of
the servo amplifier.
1 SERVO AMPLIFIER TROUBLESHOOTING