[Al. 580_Safety Communication Setting Error (Safety Sub-Function)] - Mitsubishi Electric MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MR-J5-G Series:
Table of Contents

Advertisement

[AL. 580_Safety communication setting error (safety sub-
function)]
• There is a problem with the safety communication settings.
[AL. 580.3_Safety verification code mismatch A]
Cause
1.
The safety verification code of the controller
does not match the setting of [Pr. PSC06
Safety verification code].
[AL. 580.B_Safety verification code mismatch B]
Page 189 [AL. 580.3_Safety verification code mismatch A]
Check/action method
The controller may have communicated with an unintended servo amplifier.
Check if the IP address designated in the safety communication settings of the
master station matches the IP address setting of the servo amplifier being
used.
If the IP address is correct, the safety verification code may have been set
incorrectly.
Set the values used to identify each servo amplifier in [Pr. PSC06 Safety
verification code] avoiding duplication between each piece of equipment, then
set the same values in the safety communication settings of the controller.
1 SERVO AMPLIFIER TROUBLESHOOTING
1.3 Handling methods for alarms/warnings