Honeywell Enraf 1010 CB Programming Manual page 66

Load computer
Table of Contents

Advertisement

Metering Lines (4)
Meter n
Calculate PE
Meter n
Manual PE
Meter n
Density Input
6 - 12
Enter a value in the following range:
Refer Table 6-6
Table 6-6: MPMS Equilibrium and Compressibility Calculations
Units
PSIg
kPa
When pressure correction is selected for commodity group E (NGL and
LPG), the prompt allows selecting whether to calculate the Equilibrium
Pressure or not.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG (E) and
Regulated Pm is selected as NO.
Select one of the following options:
Yes
No*
If the Pe value is not to be calculated, enter the manual value for the
Equilibrium Pressure (Pe).
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG and Calculate PE
is selected as NO
Enter a value in the following range:
Refer to Table 6-5.
Mass units with volume preset
If the arm is configured for Mass units with volume preset the operator
can setup a density probe.
Selects which density input mode to be used for density measurement.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if mass meter used with volume preset
Select one of the following options:
Model 1010 Application Pack CB
Programming Manual
Base
Entry Ranges
Temp
Compressibility Factor (F)
60 °F
0 to 65.8×10
15 °C
0 to 454.4×10
20 °C
-6
-6
Part No.: 4418024 - Rev. 1