Honeywell Enraf 1010 CB Programming Manual page 31

Load computer
Table of Contents

Advertisement

System (2)
Loading Effect Constraints: Not applicable to Emergency stop.
4 - 15
Select one of the following options for input type as System input:
Programmable Input 1
Programmable Input 2
Programmable Input 3
Programmable Input 4
Programmable Input 5
Programmable Input 6
Select one of the following options for input type as Arm Input:
Arm Input 1
Arm Input 2
Arm Input 3
Arm Input 4
Arm Input 5
Arm Input 6
Arm Input 7
Arm Input 8
Select one of the following options for input type as RIT Input and
assign that input to desired arm:
RIT Start
RIT Stop
RIT ACK
Select one of the following options:
None*
Input not used. The status of this input can still be read via SLIP
command GI.
Timeout Loading
After removal of the input and the closure of the flow control valve,
loading is paused for the time set with the Clear/Reconnect timer.
However the operator is given the option of restarting the load once
the input is restored to an active state. The load is terminated as
soon as the timer expires, and can not be restated without
performing the initial authorisation process.
Pause
Loading is paused indefinitely by the removal of the input, and the
flow control valve is closed. Loading can be resumed or discon-
tinued on reconnection of the input/permissive.
Terminate
The load is terminated as soon as the input is disconnected, and
cannot be restarted without going through the initial authorisation
process.
Model 1010 Application Pack CB
Programming Manual
Part No.: 4418024 - Rev. 1