Metering Lines (4)
Breakdown Density Allows enabling or disabling the breakdown density.
Meter n
Breakdown Density
Manual Density Allows entering of the manual density.
Meter n
Pressure Correction
6 - 8
Enter a value in the following range:
4 mA setting to Max range in Table 6-2 on page 6-7.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if density correction is enabled
Select one of the following options:
Enable
Disable*
Allows entering the breakdown density. This value is used for correction
calculations if the density probe fails.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if density correction and breakdown density is enabled
Enter a value in the following range:
4 mA Density Setting to 20 mA Density setting
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if density correction is disabled.
Enter a value in the following range:
Refer to Table 6-2 on page 6-7.
Enable to take pressure correction into account when calculating net
volumes.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if Commodity Type selected is Crude Oils (A), Refined (B) or
Lube Oils (D) or NGL and LPG (E) with Regulated PM not used.
Only if 4-20 mA input is available after configuring the temperature
and density analog probes.
Select one of the following options:
Enable
Disable*
Model 1010 Application Pack CB
Programming Manual
Part No.: 4418024 - Rev. 1