Alarm Setup - Honeywell Enraf 1010 CB Programming Manual

Load computer
Table of Contents

Advertisement

Additive Lines (6)
Edit Additive n Code Allows entry of a 10-character alphanumeric description for the injection
Pacing volume Sets how often an additive injection will occur.
Pump Off Delay Sets a time period in seconds between injections during which the
Inj n Leaking Solenoid Enables or disables the Leaking Solenoid alarm for an injection point.
Leaking Solenoid
Time Period
8 - 4
point.
Constraints: Available only when the injector point is enabled and
Select one of the following options:
10 Character alphanumeric
For example, enter "200" to inject additive once for every 200 L of
product, at 100 L, 300 L, 500 L and so on.
Constraints: Available only when the injector point is enabled and
Enter a value in the following range:
1 to 9999 (200*)
pump may continue to run. This reduces the number of pump starts.
This is applicable only during the same batch, that is, for multiple
batches. The pump will shut down immediately if the transaction is
terminated.
Enter a value in the following range:
0 to 999 seconds (0*)

8.5.2 Alarm setup

Constraints:
Available only when the injection point is enabled and assigned an
arm.
Select one of the following options:
Enable
Disable*
Enter the time period in seconds after which the leaking solenoid alarm
should be re-ported in the case where the flow exceeds the leaking
solenoid volume limit.
Constraints:
Available only when the injection point is enabled and assigned an
arm and leaking solenoid alarm is enabled.
Enter a value in following range:
0 to 9 (5*)
Model 1010 Application Pack CB
Programming Manual
assigned an arm.
assigned an arm.
Part No.: 4418024 - Rev. 1