Honeywell Enraf 1010 CB Programming Manual page 64

Load computer
Table of Contents

Advertisement

Metering Lines (4)
Meter n
Special Type
Expansion Coefficient Enter the expansion coefficient as a thermal expansion factor for the
NOTE:
Meter 1
Regulated PM
6 - 10
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Only if pressure correction and breakdown pressure is enabled
Enter a value in the following range:
4 mA Pressure Setting to 20 mA Pressure setting
Allows to select special commodity type
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Commodity Type selected is Special (C)
Select one of the following options:
Manual Entry
MTBE
Gasohol
product associated with this metering line.
Constraints: Commodity type is Special (C).
Enter a value in the following range:
Refer Table 6-4.
Table 6-4: Thermal Expansion Coefficient (Commodity Type C)
Base
Units
Temp
°F
60 °F
230.0×10
15 °C
°C
414.0×10
20 °C
For MTBE and GASOHOL the value is fixed, and can be manually entered
only if Special type selected is Manual entry.
Select whether the pressure at the meter (Pm) is regulated or not.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG (E)
Select one of the following options:
Yes
No*
Model 1010 Application Pack CB
Programming Manual
Entry Ranges
-6
-6
to 930.0×10
-6
-6
to 1674.0×10
MTBE
Gasohol
-6
789.0×10
714.34×10
-6
1420.20×10
1285.81×10
Part No.: 4418024 - Rev. 1
-6
-6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents