Honeywell Enraf 1010 CB Programming Manual page 65

Load computer
Table of Contents

Advertisement

Metering Lines (4)
Meter n
Manual DP
Meter n
Calculate FP
Meter n
Manual FP
6 - 11
If the Pm is regulated, enter the manual value for Dp.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG(E) and
Regulated PM is selected as YES.
Enter a value in the following range:
Refer to Table 6-5
Table 6-5: MPMS Equilibrium and Compressibility Calculations
Base
Units
Temp
Psig
60 °F
15 °C
kPa
20 °C
Selects whether to calculate the Compressibility Factor or not.
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode.
Available only if commodity type is NGL and LPG(E) and
Regulated PM is selected as NO.
Select one of the following options:
Yes
No*
This prompt allows entry of the manual value for the compressibility
factor (F)
Constraints:
Only available when you use the Weights and Measures switch on
the instrument to enter programming mode
and
• Commodity type is NGL and LPG(E) and Regulated PM is
selected as YES.
Or
• Regulated PM is selected as NO and calculate FP is selected as
NO.
Model 1010 Application Pack CB
Programming Manual
Entry Ranges
Equilibrium Pressure (Pe)
0 to 2200.0
0 to 15168.47
Manual Entry of Dp
0 to 2200.0
0 to 15168.47
Part No.: 4418024 - Rev. 1