Honeywell Enraf 1010 CB Programming Manual page 53

Load computer
Table of Contents

Advertisement

Loading Arms (3)
Arm n Additive Flush
Volume
NOTE:
NOTE:
Arm x Product Pacing
5 - 7
When using additives, such as dyes, selecting an additive flush volume
makes sure that the final volume does not contain any additive. Select 0
to disable flush volume.
Enter a value in the following range:
0 to 999 (0*)
Constraints: Only available if additive is configured as pulsed additive.
If a flush volume is entered, the injections will occur more frequently before
the flush volume. Once the flush volume is reached, no additive is injected.
Additive flush volume for other types of additive injectors is entered as part
of the Arm Recipe under the Recipes menu.
Sets how often an additive injection will occur. For example, enter "200"
Qty
to inject additive once for every 200L of product, at 100L, 300L, 500L
etc.
Enter a value in the following range:
0 to 9999 (200*)
Model 1010 Application Pack CB
Programming Manual
Part No.: 4418024 - Rev. 1